Copper resistive temperature transducer “needle”. Design 8

Usage

This temperature transducer is intended for temperature measurement of loose, liquid and soft media in stationary and mobile control systems of different purpose.

The resistive temperature transducer is calibrated acc. to GOST 8.461.

Construction

This temperature transducer consists of a sensing element, which is located in a sharp-ended protection tube, an accessible shaft for temperature transducer manipulation and flexible cable for a connection with an external device.

Technical Features

NSH 10М; 50М; 100М
Measuring temperature range,°С minus 50 plus 100; minus 50 plus 160
α, °С-1 0,00428
Mounting part length, mm 100
Wiring diagram (circuit) 2-wire; 3-wire; 4-wire
Class В or С
Thermal response time, no more than, s 60
Fastening Mounting to a protection sleeve
Protective fitting, mm ∅4
Recalibration interval, years 2

Connecting

A connecting with external devices is made with the help of the proper section of a flexible cable and proper amount of wires.

Design examples

Design ∅D, mm Lраб, mm Fastening NSH Class Circuit tраб,°С
ТСМ-Н 8.0.02.00.10.2.2 4 100 50М 0,00428 С 3-wire -50...+160
ТСМ-Н 8.0.02.00.11.3.3 4 100 100М 0,00428 С 4-wire -50...+100
ТСМ-Н 8.0.02.00.7.1.2 4 100 50 М 0,00428 В 2-wire -50...+160
ТСМ-Н 8.0.02.00.10.3.2 4 100 50М 0,00428 С 4-wire -50...+160
ТСМ-Н 8.0.02.00.8.1.3 4 100 100М 0,00428 B 2-wire -50...+100
ТСМ-Н 8.0.02.00.11.3.2 4 100 100М 0,00428 C 4-wire -50...+160
If you want to order not mentioned variant of design you should follow the technical features and ordering diagram of the resistive temperature transducer ТСМ-Н.