Copper Resistive Temperature TransducersTSM-N

Usage

This temperature transducer is applied for control and temperature measurement of liquid, firm, loose and gaseous media.

Fields of usage: ensure the functioning of recording devices, systems of control and automatic regulation in industry, laboratory researches, agriculture, etc.

Stability to influences

These temperature transducers correspond to climatic design group - UHL, according to GOST 15150.

The temperature transducer are stable and firm to the influence of vibration and correspond to design group N2 (acc. to GOST 12997. They are situated in areas that are damaged by the vibration from working mechanisms of industrial objects.

Protection degree - IP55 due to GOST 12254 (it’s dust-proof and protected from water jets.)

Methrological Features

These temperature transducers have standardized statistic features (NSH - the unique sensor curve) Cu10, Cu50, Cu100.

NSH, temperature coefficient resistive temperature transducer, α,°С-1, correspond to values: 0,00428.

Accuracy Classes

Acceptable tolerance limits depending to the class correspond to: for the class B: +(0,3+0,005·|t|) for the class C: +(0,6+0,01·|t|)

The temperature transducer regulated parameters and their stability during a long service life are achieved by a correct installation, usage of protective sleeves and component parts produced only by the manufacturer.

Dependence of the resistance values Cu100 of the Temperature (acc. to GOST 6651)
α=0,004280
°CΩ
-50 78,45
-45 80,62
-40 82,78
-35 84,94
-30 87,10
-25 89,26
-20 91,41
-15 93,56
-10 95,71
-5 97,86
0 100,00
5 102,14
10 104,28
15 106,42
20 108,56
25 110,69
30 112,83
35 114,97
40 117,11
45 119,25
50 121,39
55 123,53
60 125,67
65 127,80
70 129,94
75 132,08
80 134,22
85 136,36
90 138,50
95 140,64
100 142,78
105 144,91
110 147,05
115 149,19
120 151,33
125 153,47
130 155,61
135 157,75
140 159,89
145 162,02
150 164,16
155 166,30
160 168,44

The values are given without taking into consideration a cable resistance of the resistive temperature transducer with a wire always switched on.

Diagram symbols of resistive temperature transducers ТСМ-Н